Brand Name : JINGXIN
Model Number : JXJQ-Q128
Certification : ISO
Place of Origin : China
MOQ : 1 set
Price : negotiable
Payment Terms : L/C, T/T
Supply Ability : 20 per month
Delivery Time : 60 days
Packaging Details : Wooden box
Lubrication style : lubricated
Configuration : customer made
Power source : AC power
After-sales service provided : Engineers available to service machinery overseas
Dimension(l*w*h) : Vary
Warranty : 1 year
Voltage : 380 V
Working pressure : 25 MPa
Inlet pressure : 1-20 MPa
Skid mounted high capacity CNG filling station for CNG mother station
Application:
The CNG filling staion is used for mother station.
Features:
The CNG filling station have the below features.
1. The high capacity can rach 4340 Nm3/h.
2. Compressor with encloser will eliminate most of the noise.
3. The cooling method will be adopt to the local condition.
4. The compressor use our special patent and save more 10% energy.
5. Four row horizontal symmetry balance compressor will run very balancedly and with small vibration.
6. The compressor has only one cylinder in one row. It is very convenient to repair.
Technical parameters:
S/N | Model | Inlet pressure (Mpa) | Power (KW) | Capacity(Nm3/h) | Cooling style |
1 | M-9/0.5-250A-JX | 0.5 | 185 | 755 | water cooling |
2 | M-10.5/0.5-250-JX | 0.5 | 220 | 900 | water cooling |
3 | M-7.3/0.6-250A-JX | 0.6 | 160 | 660 | Mixed cooling |
4 | M-8.0/0.7-250-JX | 0.7 | 185 | 775 | Mixed cooling |
5 | M-6.3/1-250-JX | 1 | 160 | 690 | water cooling |
6 | M-8.45/1-250-JX | 1 | 220 | 950 | air cooling |
7 | M-7.3/1.4-250-JX | 1.4 | 220 | 990 | water cooling |
8 | M-3.8/2-250B-JX | 2 | 132 | 620 | Mixed cooling |
9 | M-4.5/2-250A-JX | 2 | 160 | 750 | water cooling |
10 | M-5/2-250B-JX | 2 | 185 | 870 | Mixed cooling |
11 | M-5.5/2-250-JX | 2 | 200 | 940 | water cooling |
12 | M-6.1/2-250-JX | 2 | 220 | 1035 | water cooling |
13 | M-4.5/2.5-250-JX | 2.5 | 185 | 900 | water cooling |
14 | M-5.36/2.5-250-JX | 2.5 | 220 | 1070 | water cooling |
15 | M-6.1/2.5-250-JX | 2.5 | 250 | 1220 | water cooling |
16 | M-3/3-250-JX | 3 | 132 | 660 | Mixed cooling |
17 | M-3.65/3-250A-JX | 3 | 160 | 805 | Mixed cooling |
18 | M-4.1/3-250A-JX | 3 | 185 | 930 | water cooling |
19 | M-4.9/3-250-JX | 3 | 220 | 1110 | water cooling |
20 | M-5.45/3-250B-JX | 3 | 250 | 1250 | water cooling |
21 | M-6.35/3-250-JX | 3 | 280 | 1420 | Mixed cooling |
22 | M7.1/3-250B-JX | 3 | 315 | 1595 | water cooling |
23 | M-3.65/3.5-250-JX | 3.5 | 185 | 960 | water cooling |
24 | M4.05/3-250-JX | 3.5 | 200 | 1040 | Mixed cooling |
25 | M-5.6/3.5-250-JX | 3.5 | 280 | 1450 | water cooling |
26 | M-3.4/4-250-JX | 4 | 185 | 980 | water cooling |
27 | M4.1/4-250-JX | 4 | 220 | 1170 | Mixed cooling |
28 | M-4.75/4-250-JX | 4 | 250 | 1330 | Mixed cooling |
29 | M-5.2/4-250-JX | 4 | 280 | 1490 | water cooling |
30 | M-2/6-250-JX | 6 | 132 | 760 | water cooling |
31 | M3.8/6-250-JX | 6 | 250 | 1470 | water cooling |
32 | M4.05/6-250-JX | 6 | 280 | 1630 | water cooling |
33 | M-5.4/6-250-JX | 6 | 355 | 2100 | water cooling |
34 | M-3.3/7-250-JX | 7 | 250 | 1520 | Mixed cooling |
35 | M-2.3/8-250-JX | 8 | 185 | 1170 | Mixed cooling |
36 | M3.6/8-250-JX | 8 | 280 | 1770 | water cooling |
37 | M-2.15/10/250-JX | 10 | 200 | 1345 | water cooling |
38 | M-2.36/10-250B-JX | 10 | 220 | 1480 | water cooling |
39 | M-2.75/10-250-JX | 10 | 250 | 1690 | water cooling |
40 | M-3.2/10-250-JX | 10 | 280 | 1890 | water cooling |
41 | M-3.45/10-250-JX | 10 | 315 | 2130 | water cooling |
42 | M-2.4/12-250-JX | 12 | 250 | 1780 | water cooling |
43 | M-3/12-250-JX | 12 | 315 | 2240 | water cooling |
44 | M-3.35/12-250A-JX | 12 | 355 | 2530 | water cooling |
45 | M-2.3/13-250-JX | 13 | 250 | 1830 | air cooling |
46 | M2.75/13-250-JX | 13 | 315 | 2310 | water cooling |
47 | M-2.27/14-250-JX | 14 | 250 | 1875 | Mixed cooling |
48 | M2.68/14-250-JX | 14 | 280 | 2080 | air cooling |
49 | M-1.86/15-250-JX | 15 | 220 | 1680 | Mixed cooling |
50 | M-2.7/15-250C-JX | 15 | 280 | 2150 | Mixed cooling |
51 | M-1.32/16-250-JX | 16 | 160 | 1250 | water cooling |
52 | M2.05/16-250-JX | 16 | 250 | 1965 | water cooling |
53 | M-2.6/16-250D-JX | 16 | 315 | 2470 | Mixed cooling |
54 | M-2.75/17-250-JX | 17 | 315 | 2520 | water cooling |
55 | M-2.48/18-250D-JX | 18 | 315 | 2580 | Mixed cooling |
56 | M-1.75/20-250-JX | 20 | 250 | 2110 | water cooling |
57 | M-2.1/20-250-JX | 20 | 280 | 2375 | water cooling |
58 | M-2.21/22-250-JX | 22 | 315 | 2880 | water cooling |
59 | M-2/28-250-JX | 28 | 315 | 3210 | water cooling |
60 | M-1.15/30-250-JX | 30 | 220 | 2215 | water cooling |
61 | M-1.58/30-250-JX | 30 | 280 | 2815 | water cooling |
62 | M-1.75/30-250A-JX | 30 | 315 | 3160 | Mixed cooling |
63 | M-1.5/35-250-JX | 35 | 280 | 3040 | Mixed cooling |
64 | M-1.4/40-250-JX | 40 | 280 | 3200 | Mixed cooling |
65 | M-1.5/40-250-JX | 40 | 315 | 3580 | water cooling |
66 | M-1.12/45-250-JX | 45 | 250 | 3060 | water cooling |
67 | M-1.65/45-250-JX | 45 | 355 | 4340 | water cooling |
![]() |
Skid Mounted CNG Filling Station Equipment High Capacity For CNG Mother Station Images |